Installing Stove Pipe Through Attic

Pin On Stove Indtall

Pin On Stove Indtall

Installation Of Class A Chimney With A Tee Wood Stove Wood Stove Installation Wood Stove Hearth

Installation Of Class A Chimney With A Tee Wood Stove Wood Stove Installation Wood Stove Hearth

Pin On Fireplace

Pin On Fireplace

Pin On Chimney Pipe

Pin On Chimney Pipe

Pin On Chimney

Pin On Chimney

Pin On Wood Stoves

Pin On Wood Stoves

Pin On Wood Stoves

Joe shows you how to make an attic insulation shield when space is an issue.

Installing stove pipe through attic.

Then connect it to the wall thimble. Finally install the hood. The chimney must extend at least 3 feet above the highest point where it passes through the roof and be at least 2 foot higher than any part of the building within a horizontal distance of 10 feet figure 2. Then attach the pipe to the stove and chimney pipe making sure it is rigid and tight.

Determine the number of chimney pipe lengths required. Observe your stove s clearance rating when picking a suitable spot. Sheet metal screws and seal the seams with aluminum faced duct tape not regular cloth backed duct tape. Radiating heat from the stove can pose a hazard to nearby walls and furniture so wood stoves generally have a specified clearance a minimum safe distance between the stove and nearby floors and walls.

Last fasten each section of stovepipe with self tapping screws. Install the slip connector or telescoping section last. Start with the rigid sections and work from the stove to the wall. The minimum clearance may be reduced by 50 percent to 225 mm 9 in if suitable shielding is installed either on the pipe or on the combustible surface.

If you live in an area where frost occurs add an insulated duct sleeve to the portion of pipe in the attic. Some manufacturers include a pipe kit with the stove. After trimming your pipe use black furnace cement to seal between each piece and three sheet metal screws at each joint. Wood stoves can get very very hot during use.

A flue pipe must never pass through a combustible floor or ceiling or through an attic roof space closet or concealed space. Insert the universal pipe adapter on the male end of the insulated chimney pipe. Alternatively the kits are available online or at a wood burning stove accessory store. Screw the ductwork together with 1 4 in.

Installation of the stove pipe is the same as for vertical installation. Cut the hole for the duct attach it then install the roof cap. With the provided screws attach the adapter to the pipe. 450 mm 18 in.

The termination cap is installed above this point. When you have the universal adapter connected lower the first section of the chimney pipe through the flashing and through the support box.

Installation Advice Carron Stoves Direct Stove Installation Wood Burning Stove Boiler Stoves

Installation Advice Carron Stoves Direct Stove Installation Wood Burning Stove Boiler Stoves

Wood Stove Basics Wood Stove Installation Stove Installation Portable Wood Stove

Wood Stove Basics Wood Stove Installation Stove Installation Portable Wood Stove

Chimney And Venting Wood Stove Fireplace Wood Stove Wood Stove Chimney

Chimney And Venting Wood Stove Fireplace Wood Stove Wood Stove Chimney

Flue System Internal Installation At Colesforfires Co Uk Stufa Camino

Flue System Internal Installation At Colesforfires Co Uk Stufa Camino

Source : pinterest.com